|
|
Lava™ Ultimate CAD/CAM Restorative
Real fast. Real tough. Real Easy.
What's unique about 3M ESPE's new CAD/CAM block?
Indications
It's indicated for a full range of permanent adhesive, single-unit restorations.
- Crowns, including implant-supported crowns
- Onlays
- Inlays
- Veneers
|

|
Science
The science behind nanotechnology delivers:
- Exceptional durability
- Excellent polish retention
- Less wear to opposing enamel than glass ceramics
Delivers the edge you need.
The less brittle nature of Lava Ultimate restorative allows for easy milling and better edge quality.
(l.to r.) Lava™ Ultimate CAD/CAM Restorative, feldspathic glass ceramic, lithium disilicate
SEM images MOD Tooth #3 inlays milled on a CAD/CAM system. Lava™ Ultimate CAD/CAM Restorative
exhibits less chipping at restoration margins than glass ceramics including lithium disilicate.
Source: 3M ESPE internal data
Real tough.
10-year warranty* - tough, resilient and durable.
|
Down the road, Lava Ultimate restorative will continue to perform.
The impressive durability of resin nano ceramic results from its high flexural strength and fracture toughness.
In fact, it's so tough that 3M ESPE has you covered with an industry-leading 10-Year Limited Warranty!
|

Read about Lava™ Ultimate CAD/CAM
restorative 10 year warranty
(PDF, 393KB) |
Lava™ Ultimate CAD/CAM Restorative has different material properties than feldspathic glass ceramic and composite
materials. This new material offers higher flexural strength and fracture toughness—which results in long-term durability.
Source: 3M ESPE internal data
Brilliant esthetics with a long-lasting polish.
The chairside block that was born beautiful.
| Nanotechnology on the inside means a beautiful, long-lasting polish on the outside. In fact, it takes only minutes to give your milled Lava Ultimate restorations an amazing, enamel-like luster. Tests prove the brilliant polish will last - and no firing is required. |
|
Easy to mill … and easy to work with, too!
Lava Ultimate restorative brings new meaning to the words "chairside productivity."
Your milled Lava™ Ultimate restoration can be finished in a few easy steps.
 |
- Less brittle for fracture resistance at try-in
- Very easy to adjust without weakening material
|
 |
High-speed polish without any post-firing |
 |
Easy pretreatment with Silane only - no hydrofluoric acid etching required |
 |
|
 |
Works well with self-adhesive and adhesive resin cements. For strength, performance and simplicity, RelyX™ Unicem 2 Self-Adhesive Resin Cement is ideal for Lava Ultimate restorations. |
Check out these other benefits to see how Lava™ Ultimate CAD/CAM restorative continues to
perform:
Tooth-brushing abrasion
Lava™ Ultimate Restorative - Designed for Lasting Beauty
Lava™ Ultimate CAD/CAM restorative wears far less on opposing dentition compared to glass ceramic materials
Wear Resistance
2-Body Wear Enamel Cusp Volume Loss vs. Material Disk (mm3)
Lava™ Ultimate Is Far Less Wearing on Opposing Enamel Compared to Glass Ceramic Materials
Source: University of Minnesota
Tooth-like Fluorescence
(l to r) Lava™ Ultimate A2 , Lava™ Ultimate A2
Photo courtesy of Paulo Monteiro DMD, MSC, Assistent Professor
Resilient
Modulus of Resiliency R (MPa)
Lava™ Ultimate’s Higher Resiliency Provides The Ideal Solution For A Crown Over An Implant
3M ESPE internal data
Stain Resistance
ΔE color change after 7 days storage in red wine at 37°C
Lava™ Ultimate Exhibits Excellent Stain Resistance Like Glass Ceramics
3M ESPE internal data
Plaque Resistance
Dried biomass in mg/cm2 (grown in human saliva for 26 hours)
Lava™ Ultimate Exhibits Excellent Plaque Resistance
3M ESPE internal data
Natural-looking and tough.
Real performance that outdistances glass ceramics.
A fractured partial crown made with glass ceramic material was replaced with a crown milled from
Lava™ Ultimate CAD/CAM Restorative.
Lava™ Ultimate Restorative Replacement of Ceramic Crown
(l to r) Old Glass Ceramic Restoration, New Lava™ Ultimate Restored Tooth
Lava™ Ultimate Restorative Real Chairside Productivity
Clinical case and pictures by Dr. Zafiriadis
Lava™ Ultimate Restorative Specially Suited for Implant Crowns
Available for CEREC® and E4D® chairside milling systems.
Available for CEREC AC users with software 4.0 and E4D users.
Ordering Information
Available in eight shades and two translucencies.
Shade Selection
Blocks are clearly marked with Shade/Translucency/Size. There are two sizes to choose from. Size 12. Or for larger restorations, choose size 14L.
CEREC®
|
| Lava™ Ultimate CAD/CAM Restorative Introductory Kit for CEREC® 2914SK
Kit includes: 5 blocks, size 14L: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT;
5 blocks, size 12: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT
|
|
|
|
Lava™ Ultimate CAD/CAM Restorative for CEREC® REFILLS
Kit includes: 5 blocks, size 14L: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT;
5 blocks, size 12: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT
|
|
LOW TRANSLUCENCY |
HIGH TRANSLUCENCY |
| Shade |
Size 12 |
Size 14L |
Shade |
Size 12 |
Size 14L |
| A1 |
2912A1-LT |
2914A1-LT |
A1 |
2912A1-HT |
2914A1-HT |
| A2 |
2912A2-LT |
2914A2-LT |
A2 |
2912A2-HT |
2914A2-HT |
| A3 |
2912A3-LT |
2914A3-LT |
A3 |
2912A3-HT |
2914A3-HT |
| A3.5 |
2912A3.5-LT |
2914A3.5-LT |
B1 |
2912B1-HT |
2914B1-HT |
| B1 |
2912B1-LT |
2914B1-LT |
|
|
|
| C2 |
2912C2-LT |
2914C2-LT |
|
|
|
| D2 |
2912D2-LT |
2914D2-LT |
|
|
|
| Bleach |
2912BL-LT |
2914BL-LT |
|
|
|
| |
E4D®
|
| Lava™ Ultimate CAD/CAM Restorative Introductory Kit for E4D® 3114SK
Kit includes: 5 blocks, size 14L: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT;
5 blocks, size 12: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT
|
|
|
Lava™ Ultimate CAD/CAM Restorative for E4D® REFILLS
Kit includes: 5 blocks, size 14L: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT;
5 blocks, size 12: Shades A1-LT, A2-HT, A2-LT, A3-HT, A3-LT
|
|
LOW TRANSLUCENCY |
HIGH TRANSLUCENCY |
| Shade |
Size 12 |
Size 14L |
Shade |
Size 12 |
Size 14L |
| A1 |
3112A1-LT |
3114A1-LT |
A1 |
3112A1-HT |
3114A1-HT |
| A2 |
3112A2-LT |
3114A2-LT |
A2 |
3112A2-HT |
3114A2-HT |
| A3 |
3112A3-LT |
3114A3-LT |
A3 |
3112A3-HT |
3114A3-HT |
| A3.5 |
3112A3.5-LT |
3114A3.5-LT |
B1 |
3112B1-HT |
3114B1-HT |
| B1 |
3112B1-LT |
3114B1-LT |
|
|
|
| C2 |
3112AC2-LT |
3114C2-LT |
|
|
|
| D2 |
3112D2-LT |
3114D2-LT |
|
|
|
| Bleach |
3112BL-LT |
3114BL-LT |
|
|
|
| |
|
| |
|